Switch Models and Configurations:
Cisco Catalyst 2960-L switches include a single fixed power supply. Table 1 shows configuration information.
Table 1. Cisco Catalyst 2960-L Configurations
Product ID |
10/100/1000 Ethernet Ports |
Uplink Interfaces |
Available PoE Power |
Fanless |
Dimensions (H x D x W) |
Weight |
WS-C2960L-8TS-LL |
8 |
2 SFP |
– |
Y |
1.73 x 8.45 x 10.56 in. (4.4 x 21.5 x 26.8 cm) |
4.45 lb (2.02 kg) |
WS-C2960L-8PS-LL |
8 |
2 SFP |
67W |
Y |
1.73 x 9.45 x 10.56 in. (4.4 x 24 x 26.8 cm) |
5.64 lb (2.56 kg) |
WS-C2960L-16TS-LL |
16 |
2 SFP |
– |
Y |
1.73 x 8.45 x 10.56 in. (4.4 x 21.5 x 26.8 cm) |
4.53 lb (2.06 kg) |
WS-C2960L-16PS-LL |
16 |
2 SFP |
120W |
Y |
1.73 x 9.45 x 10.56 in. (4.4 x 24 x 26.8 cm) |
5.73 lb (2.6 kg) |
WS-C2960L-24TS-LL |
24 |
4 SFP |
– |
Y |
1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) |
6.61 lb (3.0 kg) |
WS-C2960L-24PS-LL |
24 |
4 SFP |
195W |
Y |
1.73 x 10.45 x 17.5 in. (4.4 x 26.5 x 44.5 cm) |
7.63 lb (3.46 kg) |
WS-C2960L-48TS-LL |
48 |
4 SFP |
– |
Y |
1.73 x 9.45 x 17.5 in. (4.4 x 24 x 44.5 cm) |
7.21 lb (3.27 kg) |
WS-C2960L-48PS-LL |
48 |
4 SFP |
370W |
N |
1.73 x 11.5 x 17.5 in. (4.4 x 29.2 x 44.5 cm) |
10.25 lb (4.65 kg) |
Product Specifications:
Product specifications (Table 2) apply to both PoE and non-PoE models.
Table 2. Specifications
8 Port |
16 Port |
24 Port |
48 Port |
|||||||
Console Ports |
||||||||||
RJ45 Ethernet |
1 |
1 |
1 |
1 |
||||||
USB mini-B |
1 |
1 |
1 |
1 |
||||||
USB-A port for storage and Bluetooth console |
1 |
1 |
1 |
1 |
||||||
Memory and Processor |
||||||||||
CPU |
ARMv7 800 MHz |
ARMv7 800 MHz |
ARMv7 800 MHz |
ARMv7 800 MHz |
||||||
DRAM |
512 MB |
512 MB |
512 MB |
512 MB |
||||||
Flash memory |
256 MB |
256 MB |
256 MB |
256 MB |
||||||
Performance |
||||||||||
Forwarding bandwidth |
10 Gbps |
18 Gbps |
28 Gbps |
52 Gbps |
||||||
Switching bandwidth |
20 Gbps |
36 Gbps |
56 Gbps |
104 Gbps |
||||||
Forwarding rate (64-byte L3 packets) |
14.88 Mpps |
26.78 Mpps |
41.67 Mpps |
77.38 Mpps |
||||||
Unicast MAC addresses |
8K |
8K |
8K |
8K |
||||||
Maximum active VLANs |
64 |
64 |
64 |
64 |
||||||
VLAN IDs available |
4094 |
4094 |
4094 |
4094 |
||||||
Maximum STP instances |
64 |
64 |
64 |
64 |
||||||
Maximum SPAN sessions |
1 |
1 |
1 |
1 |
||||||
MTU-L3 packet |
9198 bytes |
9198 bytes |
9198 bytes |
9198 bytes |
||||||
Jumbo Ethernet frame |
10,240 bytes |
10,240 bytes |
10,240 bytes |
10,240 bytes |
||||||
MTBF in hours (Data) |
2,448,133 |
2,416,689 |
2,412,947 |
1,370,769 |
||||||
MTBF in hours (PoE) |
315,044 |
313,496 |
909,838 |
437,970 |
||||||
Environment |
||||||||||
Operating temperature |
||||||||||
At sea level |
23ºF to 131ºF (–5ºC to 55ºC) |
23ºF to 131ºF (–5ºC to 55ºC) |
23ºF to 131ºF (–5ºC to 55ºC) |
23ºF to 131ºF (–5ºC to 55ºC) |
||||||
Up to 5,000 ft |
23ºF to 113ºF (–5ºC to 45ºC) |
23ºF to 113ºF (–5ºC to 45ºC) |
23ºF to 113ºF (–5ºC to 45ºC) |
23ºF to 113ºF (–5ºC to 45ºC) |
||||||
Up to 10,000 ft |
23ºF to 104ºF (–5ºC to 40ºC) |
23ºF to 104ºF (–5ºC to 40ºC) |
23ºF to 104ºF (–5ºC to 40ºC) |
23ºF to 104ºF (–5ºC to 40ºC) |
||||||
Operating altitude |
10,000 ft (3000m) |
10,000 ft (3000m) |
10,000 ft (3000m) |
10,000 ft (3000m) |
||||||
Operating relative humidity |
5% to 90% at 40ºC |
5% to 90% at 40ºC |
5% to 90% at 40ºC |
5% to 90% at 40ºC |
||||||
Storage temperature |
–13º to 158ºF (–25º to 70ºC) |
–13º to 158ºF (–25º to 70ºC) |
–13º to 158ºF (–25º to 70ºC) |
–13º to 158ºF (–25º to 70ºC) |
||||||
Storage altitude |
15,000 ft (4500m) |
15,000 ft (4500m) |
15,000 ft (4500m) |
15,000 ft (4500m) |
||||||
Storage relative humidity |
5% to 95% at 65ºC |
5% to 95% at 65ºC |
5% to 95% at 65ºC |
5% to 95% at 65ºC |
||||||
Storage altitude |
Note: Minimum ambient temperature for cold start is 0°C (32°F) WS-C2960L-16PS-LL has maximum operating temperature of 40°C (up to 5,000 ft) and 35°C (up to 10,000 ft) |
|||||||||
Electrical |
Data |
PoE |
Data |
PoE |
Data |
PoE |
Data |
PoE |
||
Voltage (autoranging) |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
110 to 220V AC in |
||
Frequency |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
50 to 60 Hz |
||
Current |
0.13A to 0.22A |
0.22A to 0.27A |
0.16A to 0.26A |
0.24A to 0.28A |
0.20A to 0.33A |
0.21A to 0.26A |
0.29A to 0.48A |
0.37A to 0.64A |
||
Power rating (maximum consumption) |
0.04 kVA |
0.11 kVA |
0.05 kVA |
0.19 kVA |
0.06 kVA |
0.24 kVA |
0.09 kVA |
0.48 kVA |
||
Power consumption (watts) 0% traffic 10% traffic 100% traffic Weighted average |
13.0 14.8 14.9 14.2 |
19.9 22.0 22.0 21.3 |
14.9 19.3 19.3 17.8 |
21.9 27.1 27.1 25.4 |
19.4 26.5 26.5 24.1 |
25.9 32.9 32.9 30.6 |
29.7 41.1 41.1 37.3 |
68.4 81.6 81.9 77.3 |
||
Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches, cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in the endpoints. |
||||||||||
Acoustic Noise (48 Port PoE only) |
||||||||||
Sound Pressure |
LpA (Typical) |
35dB |
||||||||
LpAD (Maximum) |
39dB |
|||||||||
Sound Power |
LwA (Typical) |
4.8B |
||||||||
LwAD (Maximum) |
5.2B |
|||||||||
Note: Bystander positions operating mode at 25°C ambient. |
||||||||||
Safety and Compliance |
||||||||||
Safety |
UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1 |
|||||||||
EMC: emissions |
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A |
|||||||||
EMC: immunity |
EN55024, CISPR24, EN300386, KN24 |
|||||||||
Environmental |
Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU |
|||||||||
Telco |
Common Language Equipment Identifier (CLEI) code |
|||||||||
U.S. government certifications |
USGv6 and IPv6 Ready Logo |
|||||||||
Connectors and Interfaces |
||||||||||
Ethernet interfaces |
10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling |
|||||||||
100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling |
||||||||||
1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
||||||||||
1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
||||||||||
SFP and SFP+ interfaces |
For information about supported SFP/SFP+ modules, refer to the Transceiver Compatibility matrix tables atcisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html |
|||||||||
Indicator LEDs |
Per-port status: link integrity, disabled, activity, speed, and full duplex |
|||||||||
System status: system, PoE, and link speed |
||||||||||
Console cables |
CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45 |
|||||||||
CAB-CONSOLE-USB Console cable 6 ft. with USB Type A and mini-B connectors |
||||||||||
Power |
Use the supplied AC power cord to connect the AC power connector to an AC power outlet |
|||||||||
Management |
||||||||||
BRIDGE-MIB CISCO-CABLE-DIAG-MIB CISCO-CDP-MIB CISCO-CLUSTER-MIB CISCO-CONFIG-COPY-MIB CISCO-CONFIG-MAN-MIB CISCO-DHCP-SNOOPING-MIB CISCO-ENTITY-VENDORTYPE-OID-MIB CISCO-ENVMON-MIB CISCO-ERR-DISABLE-MIB CISCO-FLASH-MIB CISCO-FTP-CLIENT-MIB CISCO-IGMP-FILTER-MIB CISCO-IMAGE-MIB CISCO-IP-STAT-MIB CISCO-LAG-MIB CISCO-MAC-NOTIFICATION-MIB CISCO-MEMORY-POOL-MIB CISCO-PAGP-MIB CISCO-POE-EXTENSIONS-MIB |
CISCO-PORT-QOS-MIB CISCO-PORT-SECURITY-MIB CISCO-PORT-STORM-CONTROL-MIB CISCO-PRODUCTS-MIB CISCO-PROCESS-MIB CISCO-RTTMON-MIB CISCO-SMI-MIB CISCO-STP-EXTENSIONS-MIB CISCO-SYSLOG-MIB CISCO-TC-MIB CICSO-TCP-MIB CISCO-UDLDP-MIB CISCO-VLAN-IFTABLE CISCO-VLAN-MEMBERSHIP-MIB CISCO-VTP-MIB ENTITY-MIB ETHERLIKE-MIB IEEE8021-PAE-MIB IEEE8023-LAG-MIB |
IF-MIB INET-ADDRESS-MIB OLD-CISCO-CHASSIS-MIB OLD-CISCO-FLASH-MIB OLD-CISCO-INTERFACES-MIB OLD-CISCO-IP-MIB OLD-CISCO-SYS-MIB OLD-CISCO-TCP-MIB OLD-CISCO-TS-MIB RFC1213-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMP-MPD-MIB SNMP-NOTIFICATION-MIB SNMP-TARGET-MIB SNMPv2-MIB TCP-MIB UDP-MIB |
||||||||
For an updated list of supported MIBs, refer to the MIB Locator at cisco.com/go/mibs. |
||||||||||
Standards |
||||||||||
IEEE 802.1D Spanning Tree Protocol IEEE 802.1p CoS Prioritization IEEE 802.1Q VLAN IEEE 802.1s IEEE 802.1w IEEE 802.1X IEEE 802.1ab (LLDP) |
IEEE 802.3ad IEEE 802.3af and IEEE 802.3at IEEE 802.3ah (100BASE-X single/multimode fiber only) IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX |
IEEE 802.3ab 1000BASE-T IEEE 802.3z 1000BASE-X RMON I and II standards SNMP v1, v2c, and v3 IEEE 802.3az IEEE 802.3ae 10Gigabit Ethernet IEEE 802.1ax |
||||||||
RFC Compliance |
||||||||||
RFC 768 – UDP RFC 783 – TFTP RFC 791 – IP RFC 792 – ICMP RFC 793 – TCP RFC 826 – ARP RFC 854 – Telnet RFC 951 – Bootstrap Protocol (BOOTP) RFC 959 – FTP RFC 1112 – IP Multicast and IGMP RFC 1157 – SNMP v1 RFC 1166 – IP Addresses |
RFC 1256 – Internet Control Message Protocol (ICMP) Router Discovery RFC 1305 – NTP RFC 1492 – TACACS+ RFC 1493 – Bridge MIB RFC 1542 – BOOTP extensions RFC 1901 – SNMP v2C RFC 1902-1907 – SNMP v2 RFC 1981 – Maximum Transmission Unit (MTU) Path Discovery IPv6 FRC 2068 – HTTP RFC 2131 – DHCP RFC 2138 – RADIUS RFC 2233 – IF MIB v3 |
RFC 2373 – IPv6 Aggregatable Addrs RFC 2460 – IPv6 RFC 2461 – IPv6 Neighbor Discovery RFC 2462 – IPv6 Autoconfiguration RFC 2463 – ICMP IPv6 RFC 2474 – Differentiated Services (DiffServ) Precedence RFC 2597 – Assured Forwarding RFC 2598 – Expedited Forwarding RFC 2571 – SNMP Management RFC 3046 – DHCP Relay Agent Information Option RFC 3376 – IGMP v3 RFC 3580 – 802.1X RADIUS |
||||||||
Đánh giá